IPSonLab Features
New: The amount of inputs and the threshold (per input)
can be configured from within Max/Msp and Super Collider!

flow_2

   
Description   Conversion
32 x analog inputs (mulitplexed), resolution 10 bits [0-5V / 0-1024] *   Voltage (sensor info) to OSC
16 x 12 bit DA conversion. Osc to CV (0-5V or 0-10V)**   OSC - Voltage (driver)
2 x 2 bit greycode Rotary Switch connection input (counting up/down)   Greycode - OSC
8 x analog outputs (Pulse With Modulation), 
resolution 8 bits [0-256 / 0-100%] **
  OSC - PWM 
64 x On/Off Relais (Led) drive **   OSC- 64 x output
8 x servomotor drive (pulsewidth change between 1mS-2mS) **   OSC - Servo Drive
NEW: interfacing 4 Ultrasonic sensors sfr505 and sending osc distance value   4 x distance-OSC
3 Programmable control pins (send e-mails on pin-change, SMPT protocol based)   Trigger - e@mail
Sending sensor info to multiple computers  
Wireless IpSonLab with Wiport  
Takes 9-15V DC, minimum 250mA  

*  Default version resolutioin 0f 8 bit (because of communication speed reasons)
** These features are realised with different processors; Ethernet communication through UDP / OSC.
IPSonLab can be configured [ IP-address / Netmask / DNS ] through a normal web browser and telnet. IPSonLab Max/Msp-patch available for Mac (OSX) and PC. Works with an 12V/500mA DC adapter. 


Back to main